Grannus

Contentful ID
sRyqE0HAhIrtD8FLQaL9Pn1KM7BLYxBJ
Company Values
Entity Description
Grannus develops patented multi-feedstock Grannus Process™ gasification technology for producing ammonia and hydrogen.

Grannus offers a process that replaces traditional steam methane reformers with a more efficient partial oxidation boiler, resulting in the lowest emissions levels. The technology enables the construction of near-zero-emission chemical processes and power plants, producing synthetic gas for downstream chemical products and clean electric power cogeneration. It can utilize various carbonaceous feedstocks like natural gas, pet coke, and municipal solid waste, integrating a partial oxidation gas boiler with the water gas shift process to produce high hydrogen synthetic gas. The Grannus Process™ maximizes plant efficiency by utilizing 100% of the feedstock for syngas production and offering strong cogeneration capabilities.

Grannus contributes to:
Climate change mitigation by producing hydrogen and ammonia.
Entity Name
Grannus
Entity Type
Company
Is LCRI Company?
No
Tech Channel
Entry Type (Badge)

Braille Energy Systems

Contentful ID
ufBRDpNHhVOCmjtbPai6JGGM0IGSg0On
Company Values
Entity Description
Braille Energy Systems specializes in Lithium Battery solutions for both consumer and industrial applications. Braille Energy Systems develops ultra-lightweight, high-performance lithium batteries, particularly in the automotive and power sports sectors. Braille Energy Systems is distinguished for its achievements in racing and performance, being the first to introduce lithium batteries for car racing events. Additionally, the company is actively involved in the development of Emergency Back-up Power Systems for residential and industrial use, integrating seamlessly into Time-of-Use Energy Storage Systems. Braille Energy Systems Inc. develops an innovation that contributes to:<br>Climate change mitigation by developing battery solutions with improved performance.
Entity Name
Braille Energy Systems
Entity Type
Company
Is LCRI Company?
No
Tech Channel
Entry Type (Badge)

Mtm Energia Srl

Contentful ID
zbDqzAbweop3A5pegQ3GD3b8YJqi5EcT
Company Values
Entity Description
MTM Energia specializes in the production and development of cogeneration systems.

MTM Energia offers a range of solutions, including natural gas or LPG cogeneration, microcogeneration, and trigeneration systems. The comapny develops systems tailored for diverse applications such as residential, industrial, and commercial entities. Their microgeneration systems, featuring compact and reliable designs, cater to businesses with substantial energy consumption, such as hotels, nursing homes, and small industries. Additionally, MTM Energia is engaged in producing cogeneration systems powered by biogas from various sources, including livestock waste and landfills.

MTM Energia develops an innovation that contributes to:
Climate change mitigation by developing solutions contributing to sustainability
The transition to a circular economy by deriving energy from waste.
Entity Name
Mtm Energia Srl
Entity Type
Company
Is LCRI Company?
No
Tech Channel
Entry Type (Badge)

Bugera

Contentful ID
oDZSvjlSqMjyQKtSZyO0AtbREpvpderD
Company Values
Entity Description
BugEra is a pioneering company at the forefront of insect biotechnology.

specializing in the enhancement of Black Soldier Fly (BSF) traits through genetic engineering. By leveraging state-of-the-art technology, BugEra develops novel BSF strains, including the innovative BSFx2, which doubles the oil yield of black soldier fly larvae. Black Soldier Fly (BSF) larvae have a unique ability to produce oil as part of their natural biology. The oil is derived from the organic waste they consume during their larval stage. As the larvae feed on diverse organic waste streams, they metabolize the nutrients and store them in the form of oil within their bodies. This oil-rich biomass can then be harvested and processed into high-quality oil suitable for various applications, including biofuel production.

BugEra develops an innovation that contributes to:
Climate change mitigation by developing solutions that reduce reliance on fossil fuels
The transition to a circular economy by producing fuel from waste.
Entity Name
Bugera
Entity Type
Company
Is LCRI Company?
No
Tech Channel
Entry Type (Badge)

Harvest Thermal - Sarath Backend

Contentful ID
rb0CLDwIADYKIkJWknIuyKpnTk0LVj1E
Entity Description
Harvest Thermal specializes in advanced home heating, cooling, and hot water systems. Harvest Thermal provides a cloud-connected IoT and machine learning-enabled system that integrates a highly efficient electric heat pump with a thermal battery. This thermal battery charges when low-cost and environmentally friendly electricity is available, storing hot water in a tank for on-demand use. The system adjusts to weather conditions and household requirements to optimize comfort. Harvest Thermal develops an innovation that contributes to:<br>Climate change mitigation by manufacturing of energy efficiency equipment for buildings...
Entity Name
Harvest Thermal
Entity Type
Company
Is LCRI Company?
No
Tech Channel
Entry Type (Badge)

3Believe

Contentful ID
jfz2bWmQRUpBfatv3wcVODXqst1iC7Bm
Company Values
Entity Description
3beLiEVe develops battery cells for the electric vehicles market. 3beLiEVe creates high-performance automotive battery cells targeting energy density, fast charging, and long cycle life free from critical materials like cobalt and natural graphite. Sensor integration provides swift and detailed internal cell insights to enhance strategies like charging and cooling. This extends cell life and boosts safety, user acceptance, and suitability for multiple lifecycles, ultimately reducing costs. 3beLiEVe develops an innovation that contributes to:<br>Climate change mitigation through higher performance battery materials.
Entity Name
3Believe
Entity Type
Company
Is LCRI Company?
No
Tech Channel
Entry Type (Badge)

H2 Inc

Contentful ID
r4gj7KI8bNljuUnXgryTTjYknM3f19Uo
Company Values
Entity Description
H2 develops vanadium redox flow batteries, ideal for large-scale and long-duration energy storage. H2 provides vanadium redox flow batteries (VFB), ideal for large-scale and long-duration energy storage. VFB is a secondary battery for energy storage devices with a modular container-type design, a water-based electrolyte for safety, low annual capacity depletion, and a lifespan of over 20 years. It's an optimal technology for extended energy storage of 4 to 12 hours. H2 develops an innovation that contributes to:<br>Climate change mitigation by extending battery life.
Entity Name
H2 Inc
Entity Type
Company
Is LCRI Company?
No
Tech Channel
Entry Type (Badge)

Graphene Manufacturing Group

Contentful ID
ebdPLu1Z6l5P273dVJ3YxIWCq20I22ns
Company Values
Entity Description
GMG specializes in producing high-quality, scalable graphene powder from cost-effective feedstock. Graphene produced by the company is known for its thermal and electrical conductivity, which makes it suitable for various applications. THERMAL-XR Heat Transfer Coating developed by the company offers improved heat transfer capabilities, which can have applications in industries where efficient thermal management is essential, such as electronics and automotive. GMG provides graphene-enhanced lubricants. Graphene's unique properties can reduce friction and wear, potentially leading to more efficient machinery and reduced energy consumption. G Aluminium-Ion Battery: This product represents a significant innovation in energy storage technology. Aluminum-ion batteries are known for their potential to offer fast charging, longer battery life, and higher power densities compared to traditional lithium-ion batteries. GMG develops an innovation that contributes to: <br>Climate change mitigation by developing advanced materials for batteries.
Entity Name
Graphene Manufacturing Group
Entity Type
Company
Is LCRI Company?
No
Tech Channel
Entry Type (Badge)

GlassPoint

Contentful ID
eDIknPnEwgMrbUzBtFEudWvOdj8wXmUY
Entity Description
GlassPoint specializes in the development and operation of enclosed trough technology for steam production. GlassPoint employs enclosed trough technology, harnessing sunlight to produce steam with mirrors housed in a protective glass structure to minimize construction costs and operating expenses. The mirrors automatically track the sun, focusing sunlight on a stationary boiler tube to produce high-pressure steam efficiently. Additionally, GlassPoint integrates thermal storage, utilizing molten salt tanks during the day to store heat, enabling steam generation even at night for continuous operation. GlassPoint develops an innovation that contributes to:<br>Climate change mitigation by low-carbon energy generation.
Entity Name
GlassPoint
Entity Type
Company
Is LCRI Company?
No
Tech Channel
Entry Type (Badge)

Bright Day Graphene Ab

Contentful ID
ugnpAkjWwe1AicOnZ4sJQtJj5ooECfom
Entity Description
Bright Day Prototypes produce high-quality graphene material with exceptional thermal and electrical conductivity. Bright Day Prototypes graphene material has the potential to improve the efficiency and sustainability of energy storage and conversion systems, such as batteries, supercapacitors, and solar cells. The ultimate goal is to contribute to a more sustainable energy society and reduce the reliance on fossil fuels. Bright Day develops an innovation that contributes to:<br>Climate change mitigation by developing high-quality graphene material.
Entity Name
Bright Day Graphene Ab
Entity Type
Company
Is LCRI Company?
No
Tech Channel
Entry Type (Badge)