Contentful ID
269627974
Kris - Sanford
Contentful ID
y8BTf6yWW2h27TWM3nXSUhslrQn7OWCE
Company Values
Entity Description
Amet veniam officia duis non velit et occaecat cillum aute nisi excepteur.
Entity Name
Kris - Sanford
Focus Areas
General - Organization
Entity Type
National Lab
Group/Division/Lab name
Santa Rita
IP Position
7.5.3
Is LCRI Company?
Yes
Partner Reference
Technology Areas
Technology Name
Awesome Concrete Bacon
Kurchatov Institute
Contentful ID
97e1cef2-2da5-9367-1dae-563e3ab66b8e-draft
Company Values
Entity Description
Russia's National Research Center, also known as the Kurchatov Institute, is a leading nuclear research and development facility.
Entity Name
Kurchatov Institute
Focus Areas
General - Organization
Entity Type
National Lab
Is LCRI Company?
No
Technology Areas
Technology Description
Construction of the nuclear fission-fusion hybrid reactor is under construction, with start-up scheduled in 2020. A molten salt blanket will capture neutrons produced in a small tokamak fusion reactor to drive a fission reaction that relies on the thorium fuel cycle.
Technology Name
T-15MD
Los Alamos National Laboratory
Contentful ID
f1a40c2f-36d0-f5eb-1dc1-bd17fd839fc2-draft
Company Values
Entity Description
A United States Department of Energy national laboratory located in New Mexico.
Entity Name
Los Alamos National Laboratory
Focus Areas
General - Organization
Entity Type
National Lab
Is LCRI Company?
No
Technology Areas
Technology Description
A 5 MWt/2 MWe heat pipe reactor for "plug-and-go" power applications in remote installations and communities. The design is capable of rapid installation and shutdown and largely autonomous operation for 5 years without refueling. MegaPower is fueled by high-assay low enriched uranium oxide.
Technology Name
MegaPower/Special Purpose Reactor
X-Energy
Contentful ID
806b7d1a-b46b-515a-7b7b-4929cad1f7fd-draft
Company Values
Entity Description
X-Energy was formed to develop and commercialize its pebble bed high temperature gas-cooled reactor design. The company is also developing and has plans to manufacture TRISO fuel pebbles.
Entity Name
X-Energy
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The X-battery is a gas-cooled pebble bed reactor fueled by high assay LEU fuel particles, capable of autonomous operation. The 10 MWt reactor is road-transportable and can be configured to provide combined heat and power.
Technology Name
X-battery / Xe-100 MICRO reactor
Seaborg Technologies
Contentful ID
2771f9cd-7832-e746-ab4b-16e8f8fa650b-draft
Company Values
Entity Description
Seaborg is a Danish company developing a thorium MSR concept.
Entity Name
Seaborg Technologies
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The CUBE is a 150 MWt/100 MWe liquid-fueled, single fluid, thermal spectrum molten salt reactor design fueled by a combination of thorium and spent fuel from LWRs.
Technology Name
Seaborg CUBE (Compact Used fuel BurnEr) reactor
LeadCold
Contentful ID
b36a9f13-4f2c-c693-1392-e2418f790368-draft
Company Values
Entity Description
A spin-off company from the Royal Institute of Technology (KTH) in Stockholm, LeadCold is developing a small, lead-cooled reactor for remote applications, especially in the Canadian Arctic.
Entity Name
LeadCold
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
SEALER is an 8 MWt/3 MWe lead-cooled fast reactor design for remote applications. SEALER is fueled by high-assay low enriched uranium oxide fuel, and operates for 10-30 years without on-site refueling. LeadCold developed a corrosion-resistant aluminum alloyed steel for use in the reactor.
Technology Name
Swedish Advanced Lead Reactor (SEALER)
Westinghouse Electric Company, LLC
Contentful ID
2e676575-4bde-0b4c-d1ad-382d4c41216a-draft
Company Values
Entity Description
Westinghouse Electric is a nuclear technology company that offers nuclear plant design, fuel service and maintenance and control systems solutions.
Entity Name
Westinghouse Electric Company, LLC
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
Scalable, heat pipe-cooled reactor design producing combined heat and power of 0.2-25 MWe for decentralized and/or remote generation markets. The factory-built and assembled eVinci has inherent load following capabilities, rapid on-site installation potential, and infrequent refueling needs.
Technology Name
eVinci Micro Reactor
HolosGen
Contentful ID
b8a39b66-c0ef-9cf1-53ff-8267e1339239-draft
Company Values
Entity Description
Developing mobile, scalable, integral nuclear generators with simplified, containerized design.
Entity Name
HolosGen
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
High-temperature, gas-cooled reactors with an closed-loop turbojet combustion system integrated into the core unit, eliminating balance of plant (BoP) components. Dry cooling supports the combined Brayton-organic Rankine power conversion cycle, and Holos Generators are capable of high-resolution, automatic load following. The core is formed through the neutronic coupling of independently subcritical, integral power modules, actively positioned on-site by an Automatic Module Positioning System (AMPS). Entire Holos Quad generators, capable of producing up to 13 MWe without fit inside a single ISO container; the larger Holos Titan generators, housed in 12 ISO containers would be capable of producing up to 81 MWe. A smaller Holos generator for rapid deployment applications (like emergency response) would be configured for air transport and for use as stand-alone electric islands without need for substation switchyard equipment.
Technology Name
Holos Generators
NuGen
Contentful ID
dfd7c13c-6522-e9a4-8d1f-aba4051a104b-draft
Company Values
Entity Description
A nuclear technology startup founded to develop a fully integrated nuclear-fueled engine concept.
Entity Name
NuGen
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
A advanced, ultra-compact gas-cooled reactor with an energy conversion system and turbomachinery integrated into the core. Initial development efforts for the 3-50 MWe design are focused on remote locations, including space, and critical national security sites.
Technology Name
The NuGen Engine
Yellowstone Energy
Contentful ID
96740e79-0549-db81-1138-44e54c726339-draft
Company Values
Entity Description
Developing an advanced modular nuclear reactor with integrated thermal energy storage
Entity Name
Yellowstone Energy
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
A modular reactor cooled by molten nitrate salt and solid uranium oxide fuel with integrated thermal energy storage
Technology Name
Molten Nitrate Salt Reactor (MNSR)