Contentful ID
795436281

Switched Source

Contentful ID
B27g2pxylg0kelBWqqKkN
Entity Description
Switched Source is introducing next-generation distribution automation technology for utilities. These bolt-on solutions make existing distribution systems more flexible and resilient, while increasing DER hosting capacity. The equipment pays for itself with traditional value streams and “future-proofs” the grid for the rapid onset of distributed generation and electric vehicles.
Entity Name
Switched Source
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Pilots/Demonstrations
Technology Areas
Technology Description
The Phase-EQ technology is a patented power electronics device that gives utilities dynamic, dispatchable control of power from phase-to-phase in a three-phase circuit. This can be installed at feeder mid-points, or at the substation. Inter-phase balancing can be automated to make all power downstream of the device appear as perfectly balanced three-phase power to the upstream system. The Phase-EQ can also be given measurements for a different point in the feeder to “virtually” balance to that point. This technology has been supported and vetted by NYSERDA for its ability to increase solar and EV hosting of distribution systems.
Technology Name
Phase-EQ

Enertechnos

Contentful ID
1b5ca41b-c343-333e-c55f-8cfa5cb8844e-draft
Company Values
Entity Description
Enertechnos Capacitive Transfer System (CTS) cable solution aims to improve efficiency in electrical distribution grids by implementing a new form of electrical cable which offers improved performance characteristics versus traditional 33kV and 11kV cables.
Entity Name
Enertechnos
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Description
Enertechnos Capacitive Transfer System (CTS) cable is built using standard cable manufacturing equipment but arranges the conductors in a structure that creates a linear capacitor along the length of the cable. The unique line configuration and termination develops a bulk, series capacitance to balance the cable inductive reactance, which causes voltage drop and power factor issues over long distances. Performance has been simulated using 100m test cables and MATLAB® models that increase frequency to simulate longer cable lengths. Results of the models have been validated by the UK National Physical Laboratory and Brunel University. Enertechnos is focused on 33kV cables to start and can reduce to 11kV easily. Increasing voltage would require a thicker dielectric,so longer cable lengths would be required to achieve the necessary capacitance.

Sigora International Inc.

Contentful ID
b57f9fe0-0dce-241c-154b-e9d9431a1e76-draft
Company Values
Entity Description
A provider of utility management systems engineered for frontier markets
Entity Name
Sigora International Inc.
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Description
The Sigora Smart Meter and accompanying software provides mobile-enabled pre-pay, software-regulated wattage ceilings, wifi access points at meters, a secure RF-based network for transmittance of power and transactional data, and real-time theft detection and intervention. The meters can support single phase, split phase, and three-phase configurations.
Technology Name
Sigora Smart Meter

Blue Square Utilities

Contentful ID
7abdb104-2194-4e21-8394-fd008bc956de-draft
Entity Description
Blue Square Utilities is an independent smart meter installation business servicing small-medium sized energy suppliers throughout the UK. Our scope extends to the installation and maintenance of legacy and commercial metering services.
Entity Name
Blue Square Utilities
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas

Virginia Polytechnic Institute and State University

Contentful ID
aadd4bc9-1b3a-9898-9d66-ba23a81b44f6-draft
Entity Description
Virginia Tech is an educational institution that offers undergraduate and post graduate degree programs.
Entity Name
Virginia Polytechnic Institute and State University
Focus Areas
General - Organization
Entity Type
University
Group/Division/Lab name
Future Energy Electronics Center (J. Lai)
Is LCRI Company?
No
Technology Areas
Technology Description
Virginia Polytechnic Institute & State University will develop a GaN- and SiC-based, utility scale, high power (100 kW), multilevel, medium voltage DC-to-AC inverter that can receive power from sources like batteries or solar panels and transfer it directly to the medium voltage level of the utility grid. The team will also integrate the developed inverter with an existing medium voltage AC-to-DC converter to build a bidirectional solid-state transformer that converts low-voltage AC to high-voltage AC without using heavy, low-frequency materials such as copper and iron in its design. If successful, the project could lead to the first commercially viable medium voltage solid-state transformer, using just a single-stage process to obtain ultra-high efficiency power conversion.
Technology Name
Single DC Source Based Cascaded Multi-level Inverter (Category I)